Test 2021-08-26-3-5 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
Sample Information
Sample Taken Date8/26/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/1/2021
Sample typeQuality Assurance A brief description of the sampleU-bolt with HHN and Acorn Nuts
The quantity of what the sample constitutes1 lot of 450 From where was the sample collectedFabricator
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Laboratory sample identification
The fabricator/manufacturer/facility namePortland Bolt - Oregon Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-035-21 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)Not applicable
Heat Number(s)10712390 Bolt, 6215287403 HHN, 194689 Acorn Nut Nut Mfg. Lot Number(s)33753
Washer Mfg. Lot Number(s)not applicable Bolt SpecificationASTM A193B7
Bolt Length(s)9-1/2" Nut SpecificationASTM A194 Grade 2H
Washer SpecificationASTM A29 FinishHDG
Diameter/Size5/8" x 9-1/2" x 3-3/8" x 4" Bolt Mfg. Lot Numbernot applicable
Rocap Test Requirement(s)Not applicable Lubricant Requirements(s)Yes
Test Details
DIME Sample ID: 2021-08-26-3
DIME Test ID: 2021-08-26-3-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-09-02
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/02/2021
UTM:400kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1233753-621528740339681A194fsaylor

General comments (publicly viewable) (Max 1000 characters): A194
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 09/02/2021