Summary for Test 2021-08-04-34-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/04/2021 Sample Unique Key34
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/04/2021
Sample typeInformational A brief description of the sampleCombined Coldfeed
The quantity of what the sample constitutes4 Bags From where was the sample collectedSupplier
First name of sampler or witnessed byAAA Tech Last name of sampler or witnessed byAAA Tech
Title of samplerAAA Tech Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005
The fabricator's/manufacturer's product name for the sample106836 The fabricator/manufacturer designation for the sample106836
The plant number A detailed description of where the material sample was collectedBelt Feed
Where the material sample would have been placed if not sampledHMA Mix Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-04-34
DIME Test ID: 2021-08-04-34-1
Testing Lab: RMA Group - Rancho Cucamonga
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-09-01

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Marta Landaverde
Date of test: 08/04/2021
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 95 %
Cumulative percent passing the 3/8 in. sieve: 81 %
Cumulative percent passing the #4 sieve: 36 %
Cumulative percent passing the #8 sieve: 18 %
Cumulative percent passing the #16 sieve: 12 %
Cumulative percent passing the #30 sieve: 9 %
Cumulative percent passing the #50 sieve: 7 %
Cumulative percent passing the #100 sieve: 5 %
Cumulative percent passing the #200 sieve: 4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/1/2021