Summary for Test 2021-08-20-5-3

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 214640
DEA: 042J7204
EFIS: 0415000016
DIST-CO-RTE-PM04-CC-580-1.17
Award Date02/25/2021
Closeout Date12/01/2023
Work DescriptionSTEGE DRAIN SUPER-STRUCTURE, PRECAST VOIDED SLABS
Location DescriptionCONTRA COSTA COUNTY IN RICHMOND FROM 0.3 MILE EAST OF STEGE DRAIN BRIDGE TO 0.3 MILE WEST OF BAYVIEW AVENUE OVERCROSSING
QA Service Level1 (Verified on 01/27/2020)

Sample Information

Sample Taken Date08/20/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/27/2021
Sample typeVerification A brief description of the sample#8 ASTM A706 HRC 120 T Heads Lot 1
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of samplerQA Specialist Telephone number of sampler7073428602
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Fountain Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL110-120-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4109120 Head Manufacturer Lot Number(s)10020871320
Rebar Size#8 Headed Bar Model NameHRC 120 T Heads
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Steel Arizona
Head ManufacturerNucor Head FabricatorHRC Fountain Valley
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2021-08-20-5
DIME Test ID: 2021-08-20-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-09-01

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 08/31/2021
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
110.796954388030Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 9/1/2021