Test 2021-07-28-31-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 214523
DEA: 07302504
EFIS: 0713000479
DIST-CO-RTE-PM07-VEN-23-R3.3/R11.5
Work DescriptionPLACE HMA AND JPCP AND INDIVIDUAL SLAB REPLACEMENT.
Location DescriptionVENTURA COUNTY FROM ROUTE 101/23 SEPARATION TO NEW LOS ANGELES AVENUE UNDERCROSSING
Sample Information
Sample Taken Date7/28/2021 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/19/2021
Sample typeVerification A brief description of the sampleJMF 3/4" HMA-A-SP R15, 0.5% LAS
The quantity of what the sample constitutes10 Bags of Aggregate, 2 Bags of RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Sun Valley Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0482A-21
The fabricator/manufacturer/facility nameVulcan Materials Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number220831 SVA MPC A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-07-28-31
DIME Test ID: 2021-07-28-31-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-09-01
Test Results

What type of gradation is being tested?: Combined Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Calculated
Tester's full name: Satish Jain/Edmond Jabbour
Date of test: 08/24/2021
Cumulative percent passing the 2 in. sieve:100 %
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:85 %
Cumulative percent passing the 3/8 in. sieve:66 %
Cumulative percent passing the #4 sieve:48 %
Cumulative percent passing the #8 sieve:31 %
Cumulative percent passing the #16 sieve:20 %
Cumulative percent passing the #30 sieve:13 %
Cumulative percent passing the #50 sieve:8 %
Cumulative percent passing the #100 sieve:4 %
Cumulative percent passing the #200 sieve:2.5 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation