Test 2021-08-04-32-2 (AASHTO T315-20) Summary

Project Information
Project IdentifiersProject ID: 215614
DEA: 09386804
DIST-CO-RTE-PM09-MNO-168,266-1.5,4.3/11.7
Work DescriptionPLACE HMA OVER EXISTING PAVEMENT.
Location DescriptionMONO COUNTY AT AND NEAR OASIS ON ROUTE 168 AT ROUTE 266 AND ON ROUTE 266 FROM ROUTE 168 TO THE NEVADA STATE LINE
Sample Information
Sample Taken Date8/4/2021 Sample Unique Key32
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/25/2021
Sample typeAcceptance A brief description of the samplebinder, NO TEST 7/27,7/28,7/30,8/2, 8/3, 8/4
The quantity of what the sample constitutes1 can From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility namePNAC Transportation Laboratory (TL) Number661705
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA Supplier
Asphalt Binder SupplierPNAC LLC - Fernley NV MultigradeNo
Multigrade Type HMA Design ID
Test Details
DIME Sample ID: 2021-08-04-32
DIME Test ID: 2021-08-04-32-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-09-03
Test Results

Phase: Original binder
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 08/31/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.178 kPa
Phase Angle (δ) (for the 10 cycles): 64.1 degree
Complex Modulus (G*) (for the 10 measurements): 1.486 kPa
Test Temperature: 58.0 C
Dynamic Shear, G*/sin(δ): 1.65 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 standard specifications OG

Test was verified on 09/03/2021