Test 2021-08-13-15-4 (AASHTO T315-20) Summary

Project Information
Project IdentifiersProject ID: 214700
DEA: 030F2804
EFIS: 0312000069
DIST-CO-RTE-PM03-SAC-99-7.1/9.4
Work DescriptionDillard Overcrossing and McConnel Overhead
Location DescriptionHwy 99, Elk Grove, CA
Sample Information
Sample Taken Date8/13/2021 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/18/2021
Sample typeAcceptance A brief description of the samplePG64-16
The quantity of what the sample constitutes1 of 1 From where was the sample collectedSource
First name of sampler or witnessed byDerrick Last name of sampler or witnessed byMorales
Title of samplerGranite Tech Laboratory sample identification
The fabricator/manufacturer/facility nameValero Transportation Laboratory (TL) Number849116
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number5
Sublot number15 Tank number
Time of sample HMA Supplier
Asphalt Binder SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type HMA Design ID
Test Details
DIME Sample ID: 2021-08-13-15
DIME Test ID: 2021-08-13-15-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-08-30
Test Results

Phase: PAV residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 08/25/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 34.314 kPa
Phase Angle (δ) (for the 10 cycles): 49.9 degree
Complex Modulus (G*) (for the 10 measurements): 3431.087 kPa
Test Temperature: 28.0 C
(G*) x sin(δ)=: 2625 kPa
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications PAV

Test was verified on 08/30/2021