Test 2021-07-27-32-3 (ASTM D5329-16) Summary

Project Information
Project IdentifiersProject ID: 215551
DEA: 051M0104
EFIS: 0519000048
DIST-CO-RTE-PM05-MON-68-R16.8/20.0
Work DescriptionOVERLAY EXISTING ROADBED WITH RHMA (GAP GRADED).
Location DescriptionMONTEREY COUNTY IN AND NEAR SALINAS FROM 0.9 MILE EAST OF TORO PARK UNDERCROSSING TO BLANCO ROAD
Sample Information
Sample Taken Date7/27/2021 Sample Unique Key32
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/24/2021
Sample typeAcceptance A brief description of the sampleRUBBER
The quantity of what the sample constitutes1 CAN From where was the sample collectedJob Site
First name of sampler or witnessed byA Last name of sampler or witnessed byR
Title of samplerTET Laboratory sample identification
The fabricator/manufacturer/facility nameSan Joaquin Refinery Transportation Laboratory (TL) Number972768
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number1
Sublot number2 HMA Design ID
Test Details
DIME Sample ID: 2021-07-27-32
DIME Test ID: 2021-07-27-32-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-08-27
Test Results

Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 08/25/2021
Temperature: 25 C
Final Dial reading (F1): 83 mm
Ball Penetration (P1): 3 mm
Final Dial reading (F2): 82 mm
Ball Penetration (P2): 3 mm
Final Dial reading (F3): 83 mm
Ball Penetration (P3): 2 mm
Resilience 1: 20 %
Resilience 2: 21 %
Resilience 3: 19 %
Average Resilience: 20 %
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 08/27/2021