Test 2021-08-02-20-4 (AASHTO T96-02r10) Summary

Project Information
Project IdentifiersProject ID: 210227
DEA: 07286204
EFIS: 0713000217
DIST-CO-RTE-PM07-LA-138-56.20/55.20
Work DescriptionWIDEN ROUTE 138 TO 4 LANES WITH A MEDIAN TURN LANE AND STANDARD WIDTH SHOULDERS.; DRAINAGE IMPROVEMENTS.
Location DescriptionIN LOS ANGELES COUNTY IN PALMDALE FROM 87TH STREET EAST TO 96TH STREET EAST
Sample Information
Sample Taken Date8/2/2021 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/17/2021
Sample typeVerification A brief description of the samplePSUE 3/4" RHMA-G-SP 0.5% LAS
The quantity of what the sample constitutes4 Bags Of Coldfeed Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byLucas
Title of sampler Laboratory sample identification0474G-21
The fabricator/manufacturer/facility nameGranite Big Rock Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0046
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number1556 A detailed description of where the material sample was collectedBelt Cut at Granite Big Rock Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-08-02-20
DIME Test ID: 2021-08-02-20-4
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2021-08-24
Test Results

Input Type: Measured
Tester's full name: Edmond Jabbour
Date of test: 08/20/2021
Grading designation: C
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4559 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3185 grams
Percent loss after 100 revolutions:9 %
Percent loss after 500 revolutions:36 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/24/2021