Summary for Test 2021-06-02-15-6
Test performed: AASHTO T324-14Project Information
Project Identifiers | Project ID: 215245 DEA: 021J4504 EFIS: 0220000080 |
---|---|
DIST-CO-RTE-PM | 02-SIS-89-14.0/19.0 |
Award Date | 12/08/2020 |
Closeout Date | 09/27/2021 |
Work Description | PLACE HMA (TYPE A). |
Location Description | SISKIYOU COUNTY ABOUT 6 MILES NORTH OF BARTLE FROM 0.4 MILE NORTH OF EDISON CREEK ACCESS ROAD TO 2.0 MILES SOUTH OF MUD CREEK BRIDGE |
QA Service Level | 1 (Verified on 10/23/2020) |
Sample Information
Sample Taken Date | 06/02/2021 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/02/2021 |
Sample type | Acceptance | A brief description of the sample | 3/8 Type A HMA 25 RAP PG 58 34m Valero Benecia |
The quantity of what the sample constitutes | PSE 16 boxs | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Randy | Last name of sampler or witnessed by | . |
Title of sampler | CGI | Telephone number of sampler | |
Laboratory sample identification | D78818 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | JF Shea Construction, Fawndale Rock and Asphalt, Redding, CA | Transportation Laboratory (TL) Number | 858981 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/8 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-02-15
DIME Test ID: 2021-06-02-15-6
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-08-20
Test Results
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 06/07/2021
HMA Production: Field Plant Produced
Specified number of passes at 12.7 mm: 15000
Specified number of passes at inflection point: no data
Type and Amount of Anti-Stripping Additive: 1.2% Lime
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 122 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 2.6 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 2.5 mm
Stripping Inflection Point (Wheel A): >25000
Stripping Inflection Point (Wheel B): >25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 25000
Impression at specified number of passes average: 3 mm
General comments (publicly viewable) (Max 1000 characters): CT 389 required by special provision. Air voids in SGC specimens used were 7 ± 1.
Test was verified on 8/20/2021 ✔