Test 2021-08-03-26-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date8/3/2021 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/11/2021
Sample typeVerification A brief description of the sample1/2" HMA PG64-16 (Batch Plant)
The quantity of what the sample constitutes_ From where was the sample collectedManufacturer
First name of sampler or witnessed byHarish Last name of sampler or witnessed byThakur
Title of samplerTET Laboratory sample identification21-JMF-0152
The fabricator/manufacturer/facility nameTeichert Grantline Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-34-0047
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedEach Bin
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-08-03-26
DIME Test ID: 2021-08-03-26-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-08-20
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 08/16/2021
Total mass of material in the sample: 3002.3 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 176.2 grams
Cumulative mass retained on the 3/8 in. sieve: 712.4 grams
Cumulative mass retained on the #4 sieve: 1467.5 grams
Total sample mass passing the #4 sieve: 1534.2 grams
Total mass of fine material in the sample: 770 grams
Cumulative mass retained on the #8 sieve: 223.2 grams
Cumulative mass retained on the #16 sieve: 402.7 grams
Cumulative mass retained on the #30 sieve: 514.4 grams
Cumulative mass retained on the #50 sieve: 601.5 grams
Cumulative mass retained on the #100 sieve: 664.7 grams
Cumulative mass retained on the #200 sieve: 709.2 grams
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:94.1 %
Cumulative percent passing the 3/8 in. sieve:76.3 %
Cumulative percent passing the #4 sieve:51.1 %
Cumulative percent passing the #8 sieve:36.3 %
Cumulative percent passing the #16 sieve:24.4 %
Cumulative percent passing the #30 sieve:17 %
Cumulative percent passing the #50 sieve:11.2 %
Cumulative percent passing the #100 sieve:7 %
Cumulative percent passing the #200 sieve:4.03 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/20/2021