Test 2021-08-04-20-3 (AASHTO T315-20) Summary

Project Information
Project IdentifiersProject ID: 215341
DEA: 101J1204
EFIS: 1018000150
DIST-CO-RTE-PM10-MER-33-R0.0/L5.7
Work DescriptionCOLD PLANE ASPHALT CONCRETE AND PLACE HOT MIX ASPHALT.
Location DescriptionMERCED COUNTY IN AND NEAR DOS PALOS FROM FRESNO COUNTY LINE TO 0.1 MILE NORTH OF EAST JUNCTION ROUTE 152
Sample Information
Sample Taken Date8/4/2021 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/11/2021
Sample typeAcceptance A brief description of the samplePG64-16
The quantity of what the sample constitutes2 CanS From where was the sample collectedManufacturer
First name of sampler or witnessed byM Last name of sampler or witnessed byCozad
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameTeichert Santa Fe Winton Transportation Laboratory (TL) Number034071
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number1
Sublot number1 Tank number
Time of sample HMA Supplier
Asphalt Binder SupplierPacific Northwest Oil - Stockton CA MultigradeNo
Multigrade Type HMA Design ID
Test Details
DIME Sample ID: 2021-08-04-20
DIME Test ID: 2021-08-04-20-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-08-25
Test Results

Phase: RTFO residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 08/17/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.608 kPa
Phase Angle (δ) (for the 10 cycles): 82.9 degree
Complex Modulus (G*) (for the 10 measurements): 6.084 kPa
Test Temperature: 64.0 C
Dynamic Shear, G*/sin(δ): 6.13 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications RTFO

Test was verified on 08/25/2021