Summary for Test 2021-05-05-40-1
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 213411 DEA: 030H10U4 EFIS: 0317000246 |
---|---|
DIST-CO-RTE-PM | 03-SAC-5-9.7/24.9 |
Award Date | 05/01/2019 |
Closeout Date | 02/22/2024 |
Work Description | Not set |
Location Description | Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
Sample Taken Date | 05/05/2021 | Sample Unique Key | 40 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/09/2021 |
Sample type | Verification | A brief description of the sample | 3/4" Rap |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Supplier |
First name of sampler or witnessed by | J. | Last name of sampler or witnessed by | Buscheck |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Perkins Drum Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Teichert Perkins Drum Plant |
---|---|---|---|
Aggregate Size | Aggregate Source | ||
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2021-05-05-40
DIME Test ID: 2021-05-05-40-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-08-13
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Benjamin Dreher
Date of test: 06/11/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7353.8 grams
Mass of oven-dry sample in air for Sample 1: 2232.7 grams
Mass of container filled with the sample and water for Sample 1: 8721.6 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.581
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): JMf 21-023
Test was verified on 8/13/2021 ✔