Test 2021-07-29-30-5 (AASHTO T316-17) Summary

Project Information
Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
Sample Information
Sample Taken Date7/29/2021 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/10/2021
Sample typeVerification A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byQC Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0460-21
The fabricator/manufacturer/facility nameVulcan-Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Asphalt Binder SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 JMF Verification ID
Test Details
DIME Sample ID: 2021-07-29-30
DIME Test ID: 2021-07-29-30-5
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2021-08-13
Test Results

Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Babak Rezaei
Date of test: 08/13/2021
Time of test: 6:30 HH:MM
Test Temperature: 135 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 75 %
Viscosity reading #1 (A) : 0.379 Pa-s
Viscosity reading #2 (B) : 0.379 Pa-s
Viscosity reading #3 (C): 0.38 Pa-s
Average viscosity:0.379 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/13/2021