Test 2021-08-09-15-1 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 214402
DEA: 010E7704
EFIS: 0115000009
DIST-CO-RTE-PM01-HUM-101-R17.9/87.8
Work DescriptionSTRENGTHEN 2 BRIDGES.
Location DescriptionHUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD
Sample Information
Sample Taken Date8/9/2021 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/12/2021
Sample typeQuality Assurance A brief description of the sample#7 Barlock D250L Couplers
The quantity of what the sample constitutes72 Couplers From where was the sample collectedJob Site
First name of sampler or witnessed byXavier Last name of sampler or witnessed byCarrillo
Title of samplerASR Laboratory sample identification
The fabricator/manufacturer/facility nameCamblin Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC and Cascade
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#7 Coupler ModelBarlock D250L
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A200340 182336 Rebar Heat Number(s)4093000 157521
Rebar Size 2
Test Details
DIME Sample ID: 2021-08-09-15
DIME Test ID: 2021-08-09-15-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-08-12
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/12/2021
UTM:400kip
Temperature:72.00 f
Halo ID:Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 7/22mm1-0.0010.65915498590Service Splicefsaylor

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 08/12/2021