Summary for Test 2021-06-12-6-3
Test performed: ASTM D5329-16Project Information
Project Identifiers | Project ID: 213746 DEA: 080Q75U4 EFIS: 0817000114 |
---|---|
DIST-CO-RTE-PM | 08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2 |
Award Date | 04/18/2019 |
Closeout Date | 06/28/2022 |
Work Description | REPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/17/2019) |
Sample Information
Sample Taken Date | 06/12/2021 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/15/2021 |
Sample type | Acceptance | A brief description of the sample | Asphalt Rubber Binder |
The quantity of what the sample constitutes | 1Quart can | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Vulcan QC | Last name of sampler or witnessed by | Vulcan QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Matich-Cabazon | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-12-6
DIME Test ID: 2021-06-12-6-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-08-11
Test Results
Input Type: Calculated
Tester's full name: Majid Essa
Date of test: 08/10/2021
Temperature: 25 C
Final Dial reading (F1): 83 mm
Ball Penetration (P1): 5 mm
Final Dial reading (F2): 85 mm
Ball Penetration (P2): 4 mm
Final Dial reading (F3): 84 mm
Ball Penetration (P3): 4 mm
Resilience 1: 22 %
Resilience 2: 19 %
Resilience 3: 20 %
Average Resilience: 20 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/11/2021 ✔