Summary for Test 2021-07-06-36-10

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/06/2021 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/14/2021
Sample typeAggregate Prequalification Program A brief description of the sampleNatural Sand
The quantity of what the sample constitutes150 lbs From where was the sample collectedSource
First name of sampler or witnessed byMichael Last name of sampler or witnessed byMaldonado
Title of samplerQuality Control Telephone number of sampler
Laboratory sample identification4328 Linked DIME Sample ID2021-07-06-1
The fabricator/manufacturer/facility nameVulcan Reliance Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0016::RELIANCE - IRWINDALE
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-07-06-36
DIME Test ID: 2021-07-06-36-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2021-08-09

Test Results


Number of tests: 2
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 07/27/2021
Temperature correction: 72
Temperature of solution: 72
Clay reading (test 1): 4.7
Sand reading (test 1): 4.2
Clay reading (test 2): 4.8
Sand reading (test 2): 4.2
Sand equivalent (test 1): 90
Sand equivalent (test 2): 88
Sand equivalent before temperature correction: 89
Sand equivalent after temperature correction: 89
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/9/2021