Summary for Test 2021-05-24-56-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215424
DEA: 024G4404
EFIS: 0214000013
DIST-CO-RTE-PM02-SIS-3-38.0/38.6
Award Date04/05/2021
Closeout Date08/14/2023
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD
QA Service Level1 (Verified on 01/19/2021)

Sample Information

Sample Taken Date05/24/2021 Sample Unique Key56
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/24/2021
Sample typeVerification A brief description of the sample1/2-inch RAP (Combined)
The quantity of what the sample constitutesVerification of JMF 21-04-S01 From where was the sample collectedManufacturer
First name of sampler or witnessed byDevin Last name of sampler or witnessed byOwens
Title of sampler Telephone number of sampler
Laboratory sample identificationD78807B Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis - Nortstate Asphalt, Redding, CA Transportation Laboratory (TL) Number897294
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceTullis, Northstate Asphalt, Redding, CA
Aggregate Size1/2-inch Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-24-56
DIME Test ID: 2021-05-24-56-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-08-12

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 05/26/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1696.5 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1589.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 6.28 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/12/2021