Summary for Test 2015-09-10-4-1

Test performed: ASTM C1064-12

Project Information

Project IdentifiersProject ID: 209187
DEA: 04235624
EFIS: 0400000678
COOP: 042583
DIST-CO-RTE-PM04-SCL,SM-101-52.0/52.6,0.0/0.6
Award Date04/28/2015
Closeout Date01/08/2020
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSANTA CLARA AND SAN MATEO COUNTIES IN PALO ALTO AND EAST PALO ALTO FROM OREGON EXPRESSWAY OVERCROSSING TO 0.3 MILE SOUTH OF UNIVERSITY AVENUE OVERCROSSING
QA Service Level1 (Verified on 12/11/2013)

Sample Information

Sample Taken Date09/10/2015 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2015
Sample typeQuality Control A brief description of the sample4 EA 6x12 Compression Cylinder
The quantity of what the sample constitutesOne Day of Concrete Pour From where was the sample collectedJob Site
First name of sampler or witnessed byMark Last name of sampler or witnessed byAlexander
Title of samplerQC Technician Telephone number of sampler5106141044
Laboratory sample identification150157 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCentral Concrete Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier350348
Structure nameAbutment Footing Number 1

Material Information

Material TypeConcrete The concrete mix design numberD15PP562
The truck number from where the sample was collected1228 The batch plant ticket number from where the sample was collected18086437
Concrete batch plant3 The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedTruck Chute Where the material sample would have been placed if not sampledAbutment Footing Number 1
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-09-10-4
DIME Test ID: 2015-09-10-4-1
Testing Lab: Summit Associates
Test Method: ASTM C1064-12: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2015-09-22

Test Results


Input Type: Calculated
Tester's full name: Mark Alexander
Date of test: 09/10/2015
Temperature: 87 F
General comments (publicly viewable) (Max 1000 characters): Maximum Temperature 90 F

Test was verified on 9/22/2015