Summary for Test 2021-06-01-40-5

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/01/2021 Sample Unique Key40
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/21/2021
Sample typeVerification A brief description of the samplePG64-10/16
The quantity of what the sample constitutes1 can From where was the sample collectedSource
First name of sampler or witnessed by_ Last name of sampler or witnessed by_
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMarathon - Bakersfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number25001
Time of sample0830 HMA Supplier
Certified Asphalt SupplierMarathon Petroleum Co. LP - Bakersfield CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-01-40
DIME Test ID: 2021-06-01-40-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-09-07

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 07/27/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 43.554 kPa
Phase Angle (δ) (for the 10 cycles): 46.6 degree
Complex Modulus (G*) (for the 10 measurements): 4355.458 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 3165 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications PAV - DSR

Test was verified on 9/7/2021