Test 2015-08-12-2-1 (ASTM C39-17a) Summary

Project Information
Project IdentifiersProject ID: 208852
DEA: 040A5344
EFIS: 0400021131
COOP: 042491
DIST-CO-RTE-PM04-SOL-80,80-R11.4/13.0
Work DescriptionREALIGN I-680 TO CONNECT DIRECTLY WITH THE I-80/SR-12 INTERCHANGE.
Location DescriptionIN SOLANO COUNTY NEAR FAIRFIELD.
Sample Information
Sample Taken Date8/12/2015 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/14/2015
Sample typeQuality Control A brief description of the sampleconcrete
The quantity of what the sample constitutescylinders From where was the sample collectedJob Site
First name of sampler or witnessed byJose Last name of sampler or witnessed byDe La F
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameunknown Transportation Laboratory (TL) Number93405
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown
Material Information
Material TypeConcrete The concrete mix design numberunknown
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedUnknown
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedtailgate Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set
Test Details
DIME Sample ID: 2015-08-12-2
DIME Test ID: 2015-08-12-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-09-09
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bang
Date of test: 09/09/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 137533 lb
Maximum load on cylinder 2: 144673 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 4847.8 psi
Compressive strength of cylinder 2: 5099.5 psi
Compressive strength (to nearest 10 psi):4970 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 09/09/2015