Summary for Test 2021-05-18-59-2
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 214515 DEA: 024F6004 EFIS: 0213000012 |
---|---|
DIST-CO-RTE-PM | 02-SIS,TRI-36,96,299-VAR |
Award Date | 01/14/2020 |
Closeout Date | 08/24/2022 |
Work Description | BRIDGE DECK REPAIR, POLYESTER OVERLAY AND RAIL REPLACEMENT. |
Location Description | SISKIYOU AND TRINITY COUNTIES AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
Sample Taken Date | 05/18/2021 | Sample Unique Key | 59 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/18/2021 |
Sample type | Verification | A brief description of the sample | 1/2-inch Type A HMA (PG 64-28 M) |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78802 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Mercer-Fraser Company, Willow Creek Plant, Willow Creek, CA | Transportation Laboratory (TL) Number | 815633 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-05-18-59
DIME Test ID: 2021-05-18-59-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-07-23
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 05/19/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7336.6 grams
Mass of oven-dry sample in air for Sample 1: 1694.3 grams
Mass of container filled with the sample and water for Sample 1: 8394.5 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.662
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/23/2021 ✔