Test 2021-07-13-19-5 (ASTM D217-16) Summary

Project Information
Project IdentifiersProject ID: 214945
DEA: 051G1304
EFIS: 0514000110
DIST-CO-RTE-PM05-SB-1-M29.9/49.2
Work DescriptionCOLD PLANE AC PAVEMENT, PLACE RHMA-G & HMA (TYPE A).
Location DescriptionSANTA BARBARA COUNTY NEAR SANTA MARIA FROM CALIFORNIA BOULEVARD TO ROUTE 166
Sample Information
Sample Taken Date7/13/2021 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/20/2021
Sample typeAcceptance A brief description of the samplebinder
The quantity of what the sample constitutes1 can From where was the sample collectedSource
First name of sampler or witnessed byplant operator Last name of sampler or witnessed byplant operator
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameWorld Oil Transportation Laboratory (TL) Number210713C
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number1537
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2021-07-13-19
DIME Test ID: 2021-07-13-19-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2021-07-23
Test Results

Determination: Unworked Penetration
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 07/23/2021
Unworked Penetration, Test 1: 36 0.1 mm
Unworked Penetration, Test 2: 36 0.1 mm
Unworked Penetration, Test 3: 38 0.1 mm
Unworked Penetration:37 0.1 mm
General comments (publicly viewable) (Max 1000 characters): 2018 per spec.

Test was verified on 07/23/2021