Summary for Test 2021-07-13-19-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 214945
DEA: 051G1304
EFIS: 0514000110
DIST-CO-RTE-PM05-SB-1-M29.9/49.2
Award Date07/08/2020
Closeout Date10/21/2022
Work DescriptionCOLD PLANE AC PAVEMENT, PLACE RHMA-G & HMA (TYPE A).
Location DescriptionSANTA BARBARA COUNTY NEAR SANTA MARIA FROM CALIFORNIA BOULEVARD TO ROUTE 166
QA Service Level1 (Verified on 09/03/2020)

Sample Information

Sample Taken Date07/13/2021 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/20/2021
Sample typeAcceptance A brief description of the samplebinder
The quantity of what the sample constitutes1 can From where was the sample collectedSource
First name of sampler or witnessed byplant operator Last name of sampler or witnessed byplant operator
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWorld Oil Transportation Laboratory (TL) Number210713C
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number1537
Sublot number Asphalt Rubber Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-07-13-19
DIME Test ID: 2021-07-13-19-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-07-23

Test Results


Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 07/23/2021
Temperature: 25 C
Final Dial reading (F1): 78 mm
Ball Penetration (P1): 2 mm
Final Dial reading (F2): 79 mm
Ball Penetration (P2): 4 mm
Final Dial reading (F3): 79 mm
Ball Penetration (P3): 5 mm
Resilience 1: 24 %
Resilience 2: 25 %
Resilience 3: 26 %
Average Resilience: 25 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): 2018 per spec.

Test was verified on 7/23/2021