Test 2021-05-13-37-4 (AASHTO T269-14) Summary

Project Information
Project IdentifiersProject ID: 212496
DEA: 024E4504
EFIS: 0200020286
DIST-CO-RTE-PM02-LAS,MOD-139,299-VAR
Work DescriptionPLACE HMA, REPLACE DRAINAGE, CULVERT, ELECTRICAL AND LIGHTING SYSTEMS.
Location DescriptionLASSEN AND MODOC COUNTIES ON ROUTE 139 AT 0.1 MILE NORTH OF LASSEN COUNTY LINE AND ON ROUTE 299 AT VARIOUS LOCATONS FROM 0.4 MILE WEST OF BOYD HILL LOOKOUT ROAD TO 0.6 MILE EAST OF COUNTY ROAD 87
Sample Information
Sample Taken Date5/13/2021 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/14/2021
Sample typeAcceptance A brief description of the sample3/4-inch Type A HMA (eq. PG 64-28 M)
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byEmilio Last name of sampler or witnessed byChavez
Title of sampler Laboratory sample identificationD78795
The fabricator/manufacturer/facility nameHat Creek Construction and Materials - Shaw Pit Facility - Lookout, CA Transportation Laboratory (TL) Number765845
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2021-05-13-37
DIME Test ID: 2021-05-13-37-4
Testing Lab: CT D02 - North Region Materials Lab
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2021-07-20
Test Results

Number of tests: 3
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 07/16/2021
Bulk Specific Gravity: 2.362
Bulk Specific Gravity 2: 2.365
Bulk Specific Gravity 3: 2.363
Theoretical Maximum Specific Gravity: 2.451
Percent Air Voids: 3.6 %
Percent Air Voids 2: 3.5
Percent Air Voids 3: 3.6
Percent Air Voids Average:3.6
General comments (publicly viewable) (Max 1000 characters): VMA = 14.5, VFA = 75.4, DP = 1.4

Test was verified on 07/20/2021