Summary for Test 2021-06-24-26-1
Test performed: AASHTO T30-19Project Information
Project Identifiers | Project ID: 214586 DEA: 081H7704 EFIS: 0817000132 |
---|---|
DIST-CO-RTE-PM | 08-SBD-215-4.5/5.8 |
Award Date | 06/10/2020 |
Closeout Date | 05/26/2022 |
Work Description | INSTALL SIGN STRUCTURE, HMA, MODIFY RAMP METERING AND RETAINING WALL. |
Location Description | SAN BENARDINO COUNTY IN SAN BERNARDINO FROM 0.5 MILE SOUTH OR ORANGE SHOW ROAD/AUTO PLAZA DRIVE OVERCROSSING TO 0.2 MILE NORTH OF INLAND CENTER DRIVE OVERCROSSING |
QA Service Level | 1 (Verified on 04/16/2020) |
Sample Information
Sample Taken Date | 06/24/2021 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/24/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1 Bag |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Julius | Last name of sampler or witnessed by | E |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 827 tons out | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | All American Asphalt Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-24-26
DIME Test ID: 2021-06-24-26-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2021-07-19
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Calculated
Tester's full name: Julius E
Date of test: 06/28/2021
Cumulative percent passing the 2 in. sieve: 0 %
Cumulative percent passing the 1 1/2 in. sieve: 0 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 95 %
Cumulative percent passing the 1/2 in. sieve: 77 %
Cumulative percent passing the 3/8 in. sieve: 62 %
Cumulative percent passing the #4 sieve: 41 %
Cumulative percent passing the #8 sieve: 28 %
Cumulative percent passing the #16 sieve: 19 %
Cumulative percent passing the #30 sieve: 12 %
Cumulative percent passing the #50 sieve: 7 %
Cumulative percent passing the #100 sieve: 6 %
Cumulative percent passing the #200 sieve: 3.1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/19/2021 ✔