Test 2021-07-02-7-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
Sample Information
Sample Taken Date7/2/2021 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/15/2021
Sample typePer Request A brief description of the sample#5 HRC
The quantity of what the sample constitutes32 From where was the sample collectedJob Site
First name of sampler or witnessed byNestor Last name of sampler or witnessed byAlvarez
Title of samplerInspector Laboratory sample identification
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelHRC 500 / 510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)HRC 500 Heat 74120293 HRC 510 Heat 7312029 Rebar Heat Number(s)4107214
Rebar Size 2
Test Details
DIME Sample ID: 2021-07-02-7
DIME Test ID: 2021-07-02-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-07-19
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/15/2021
UTM:400kip
Temperature:72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 5/16mm100.312882892994OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 07/19/2021