Summary for Test 2021-05-25-36-2

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215253
DEA: 021J4804
EFIS: 0220000083
DIST-CO-RTE-PM02-SHA,TRI-36-8.0/11.912,27.1/R41.139
Award Date02/05/2021
Closeout Date09/30/2021
Work DescriptionASPHALT RUBBER CHIP SEAL AND TRAFFIC STRIPE.
Location DescriptionSHASTA AND TRINITY COUNTIES AT AND NEAR PLATINA FROM 0.4 MILE EAST OF MIDDLE FORK COTTONWOOD CREEK BRIDGE TO BEEGUM CREEK BRIDGE AND FROM 1.3 MILES EAST OF BRAMLET ROAD TO SHASTA COUNTY LINE
QA Service Level1 (Verified on 10/30/2020)

Sample Information

Sample Taken Date05/25/2021 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/23/2021
Sample typeAcceptance A brief description of the samplePG58-22
The quantity of what the sample constitutes1 can From where was the sample collectedSource
First name of sampler or witnessed byD. Last name of sampler or witnessed byOWENS
Title of samplerPEI Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero-Benicia Asphalt Plant Transportation Laboratory (TL) NumberNot Provided
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-25-36
DIME Test ID: 2021-05-25-36-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-07-13

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 07/12/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.278 kPa
Phase Angle (δ) (for the 10 cycles): 83.4 degree
Complex Modulus (G*) (for the 10 measurements): 2.314 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 2.33 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications ORG

Test was verified on 7/13/2021