Test 2021-06-29-35-7 (AASHTO T315-16) Summary

Project Information
Project IdentifiersProject ID: 215348
DEA: 060U4204
EFIS: 0616000004
DIST-CO-RTE-PM06-FRE-99-R4.9/11.6
Work DescriptionCONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location DescriptionFRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
Sample Information
Sample Taken Date6/29/2021 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/8/2021
Sample typeAcceptance A brief description of the sampleBinder
The quantity of what the sample constitutes1 Can, #1 Test From where was the sample collectedJob Site
First name of sampler or witnessed byNoah Last name of sampler or witnessed byHunt
Title of samplerConsultant Laboratory sample identification
The fabricator/manufacturer/facility nameSan Joaquin Refining Transportation Laboratory (TL) Number039805
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number1
Sublot number1 Tank number
Time of sample HMA SupplierSecurity
Asphalt Binder SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type HMA Design ID
Test Details
DIME Sample ID: 2021-06-29-35
DIME Test ID: 2021-06-29-35-7
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-07-14
Test Results

Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 07/13/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 58.008 kPa
Phase Angle (δ) (for the 10 cycles): 56.9 degree
Complex Modulus (G*) (for the 10 measurements): 5795.292 kPa
Test Temperature: 34.0 C
(G*) x sin(δ)=: 4855 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications PAV

Test was verified on 07/14/2021