Summary for Test 2021-06-16-16-1

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 214618
DEA: 033F99U4
EFIS: 0319000311
DIST-CO-RTE-PM03-SUT-99-39.2/41.4
Award Date05/15/2020
Closeout Date12/13/2023
Work DescriptionWIDEN RDWY, HMA, CRCP, WATER LINE, SIGNALS, & LIGHTING SYSTEM.
Location DescriptionSUTTER COUNTY IN AND NEAR LIVE OAK FROM 0.1 MILE SOUTH OF COLEMAN AVENUE TO NEVADA STREET (NORTH INTERSECTION)
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date06/16/2021 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/21/2021
Sample typeAcceptance A brief description of the samplePG58-22
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed byBrad Last name of sampler or witnessed byMcKeehan
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2021-06-02-24
The fabricator/manufacturer/facility nameValero Benicia Transportation Laboratory (TL) Number706335
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA SupplierDeSilva Gates
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-16-16
DIME Test ID: 2021-06-16-16-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-07-15

Test Results


Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 07/13/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 171.431 grams
Mass of empty container #2: 165.576 grams
Mass of container #1 before test (m1i): 206.516 grams
Mass of container #2 before test (m2i): 201.983 grams
Mass of container #1 after test (m1f): 206.371 grams
Mass of container #2 after test (m2f): 201.831 grams
Average mass change: -0.415 percent
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 7/15/2021