Summary for Test 2021-06-18-17-2

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 215441
DEA: 021J5204
EFIS: 0220000087
DIST-CO-RTE-PM02-MOD,SIS-139-34.0/50.7,0.0/5.0
Award Date03/02/2021
Closeout Date09/27/2021
Work DescriptionPLACE ASPHALT RUBBER BINDER CHIP SEAL & REPLACE AC SURFACING.
Location DescriptionMODOC AND SISKIYOU COUNTIES AT AND NEAR NEWELL FROM 3.3 MILES NORTH OF PEREZ OVERHEAD TO ROUTE 161
QA Service Level1 (Verified on 02/01/2021)

Sample Information

Sample Taken Date06/18/2021 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/02/2021
Sample typeAcceptance A brief description of the sampleRubberized PG58-22
The quantity of what the sample constitutes1 of 1 gallon can From where was the sample collectedDistributor
First name of sampler or witnessed byJacob Last name of sampler or witnessed byS
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAlbina - Klamath Falls Transportation Laboratory (TL) Numberc815583
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 58-22 Lot number
Sublot number Asphalt Rubber Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-18-17
DIME Test ID: 2021-06-18-17-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-07-09

Test Results


Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 07/08/2021
Temperature: 25 C
Final Dial reading (F1): 93 mm
Ball Penetration (P1): 3 mm
Final Dial reading (F2): 95 mm
Ball Penetration (P2): 6 mm
Final Dial reading (F3): 95 mm
Ball Penetration (P3): 6 mm
Resilience 1: 10 %
Resilience 2: 11 %
Resilience 3: 11 %
Average Resilience: 11 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 7/9/2021