Test 2021-06-15-44-2 (ASTM D5329-16) Summary

Project Information
Project IdentifiersProject ID: 215441
DEA: 021J5204
EFIS: 0220000087
DIST-CO-RTE-PM02-MOD,SIS-139-34.0/50.7,0.0/5.0
Work DescriptionPLACE ASPHALT RUBBER BINDER CHIP SEAL & REPLACE AC SURFACING.
Location DescriptionMODOC AND SISKIYOU COUNTIES AT AND NEAR NEWELL FROM 3.3 MILES NORTH OF PEREZ OVERHEAD TO ROUTE 161
Sample Information
Sample Taken Date6/15/2021 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/2/2021
Sample typeAcceptance A brief description of the sampleRubberized PG58-22
The quantity of what the sample constitutes1 of 1 gallon can From where was the sample collectedDistributor
First name of sampler or witnessed byJ Last name of sampler or witnessed byC
Title of samplerConsultant Laboratory sample identification
The fabricator/manufacturer/facility nameAlbina - Klamath Falls Transportation Laboratory (TL) Numberc990930
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 58-22 Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2021-06-15-44
DIME Test ID: 2021-06-15-44-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-07-09
Test Results

Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 07/08/2021
Temperature: 25 C
Final Dial reading (F1): 95 mm
Ball Penetration (P1): 3 mm
Final Dial reading (F2): 96 mm
Ball Penetration (P2): 6 mm
Final Dial reading (F3): 94 mm
Ball Penetration (P3): 6 mm
Resilience 1: 8 %
Resilience 2: 10 %
Resilience 3: 12 %
Average Resilience: 10 %
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 07/09/2021