Test 2021-06-29-2-1 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 88888
DEA: STOCK
EFIS: STOCK
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
Sample Information
Sample Taken Date6/29/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing7/6/2021
Sample typeQuality Assurance A brief description of the sample3/4"-11
The quantity of what the sample constitutes16 Samples out of 18,000 pcs. From where was the sample collectedManufacturer
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byMarin
Title of samplerAMR Laboratory sample identification
The fabricator/manufacturer/facility nameBlue Circle Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL133-078-21 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)ALTON Steel 2011781 Nut Mfg. Lot Number(s)33774-201781
Washer Mfg. Lot Number(s)N/A Bolt SpecificationN/A
Bolt Length(s)N/A Nut SpecificationASTM A563
Washer SpecificationN/A FinishASTM A563
Diameter/Size3/4"-11 Bolt Mfg. Lot NumberN/A
Rocap Test Requirement(s)Unknown Lubricant Requirements(s)Unknown
Test Details
DIME Sample ID: 2021-06-29-2
DIME Test ID: 2021-06-29-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-07-08
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/08/2021
UTM:450kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1133774-20178152904Nut Prooffsaylor

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 07/08/2021