Summary for Test 2021-06-14-41-2

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 212324
DEA: 033F5104
EFIS: 0313000020
DIST-CO-RTE-PM03-YUB-20-R18.1/R20.1
Award Date10/31/2019
Closeout Date08/03/2023
Work DescriptionConstruct bridge, realign curve & widen shoulders.
Location DescriptionConstruction on state highway in Yuba County near Smartsville from the Yuba River Bridge to 0.3 mile east of Smartsville Road.
QA Service Level1 (Verified on 02/27/2020)

Sample Information

Sample Taken Date06/14/2021 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/02/2021
Sample typeAcceptance A brief description of the samplePG64-16
The quantity of what the sample constitutes1 can From where was the sample collectedSource
First name of sampler or witnessed byNot Provided Last name of sampler or witnessed byNot Provided
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMarathon Transportation Laboratory (TL) Numberc930937
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number1
Sublot number1 Tank number
Time of sample HMA SupplierTeichert
Certified Asphalt SupplierMarathon Petroleum Co. LP - Elk Grove CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-14-41
DIME Test ID: 2021-06-14-41-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-07-09

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 07/06/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.175 kPa
Phase Angle (δ) (for the 10 cycles): 87.4 degree
Complex Modulus (G*) (for the 10 measurements): 1.456 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.46 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications ORG

Test was verified on 7/9/2021