Summary for Test 2015-07-17-6-1

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 209676
DEA: 023E7904
EFIS: 0200020151
DIST-CO-RTE-PM02-TRI-299-12.3/12.9
Award Date09/24/2014
Closeout Date11/29/2017
Work DescriptionCollins Bar Sidehill Viaduct
Location DescriptionTrinity County
QA Service Level1 (Verified on 06/20/2014)

Sample Information

Sample Taken Date07/17/2015 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/03/2015
Sample typeAnnual Source Testing A brief description of the sample1x4
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byBrace
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification15CPCC-0336 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameEureka Ready Mix Transportation Laboratory (TL) NumberC899641A
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)NA
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2015-07-17-6
DIME Test ID: 2015-07-17-6-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2015-08-17

Test Results


What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Thomas Stinnett
Date of test: 08/03/2015
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 10.8 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/17/2015