Test 2021-06-14-5-1 (ASTM F606-14) Summary

Project Information
Project IdentifiersProject ID: 214922
DEA: 100X3104
EFIS: 1013000265
DIST-CO-RTE-PM10-SJ-99-16.8/17.6
Work DescriptionREPLACE BRIDGE.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF FARMINGTON ROAD OVERCROSSING
Sample Information
Sample Taken Date6/14/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/14/2021
Sample typeQuality Assurance A brief description of the sampleAnchor Bolt Hardware
The quantity of what the sample constitutes21 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Laboratory sample identificationna
The fabricator/manufacturer/facility nameUniversal Industrial Sales Inc Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-080-21 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)3101909 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationF1554
Bolt Length(s)12" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size3/4" Bolt Mfg. Lot Number3101909
Rocap Test Requirement(s)na Lubricant Requirements(s)na
Test Details
DIME Sample ID: 2021-06-14-5
DIME Test ID: 2021-06-14-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2021-07-01
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/01/2021
UTM:400kip
Temperature:72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11UNC 3/4 0.33431364139938947963026596F1554 Axial Tinsel

General comments (publicly viewable) (Max 1000 characters): F1554 Axial Tinsel
Test Graph
Source: Bluehill Data Point File

Test was verified on 07/01/2021