Test 2021-06-14-10-1 (ASTM F606-14) Summary

Project Information
Project IdentifiersProject ID: 214922
DEA: 100X3104
EFIS: 1013000265
DIST-CO-RTE-PM10-SJ-99-16.8/17.6
Work DescriptionREPLACE BRIDGE.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF FARMINGTON ROAD OVERCROSSING
Sample Information
Sample Taken Date6/14/2021 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/14/2021
Sample typeQuality Assurance A brief description of the sampleA449 Fully threaded Rod, HDG
The quantity of what the sample constitutes465 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Laboratory sample identificationna
The fabricator/manufacturer/facility nameUniversal Industrial Sales Inc Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-080-21 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)10658640 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt Specificationna
Bolt Length(s)12" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size5/8" Bolt Mfg. Lot Number33972
Rocap Test Requirement(s)na Lubricant Requirements(s)na
Test Details
DIME Sample ID: 2021-06-14-10
DIME Test ID: 2021-06-14-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2021-07-01
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/01/2021
UTM:400kip
Temperature:72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11UNC 5/8 0.2263067013613570612820028973A449 Axial Tinsel

General comments (publicly viewable) (Max 1000 characters): A449 Axial Tinsel
Test Graph
Source: Bluehill Data Point File

Test was verified on 07/01/2021