Summary for Test 2021-06-21-14-4

Test performed: ASTM D217-16

Project Information

Project IdentifiersProject ID: 215412
DEA: 061A9404
EFIS: 0620000141
DIST-CO-RTE-PM06-FRE-5-20.0/21.0,30.9/37.3
Award Date02/18/2021
Closeout Date11/23/2021
Work DescriptionCOLD PLANE AND REPLACE WITH RHMA (TYPE O).
Location DescriptionFRESNO COUNTY FROM 2 MILES NORTH OF ROUTE 5/33/145 SEPARATION TO SOUTH DERRIC AVENUE OVERCROSSING AND FROM 1 MILE NORTH OF ROUTE 5/33 SEPARATION TO 1.1 MILES SOUTH OF KAMM AVENUE OVERCROSSING
QA Service Level1 (Verified on 01/25/2021)

Sample Information

Sample Taken Date06/21/2021 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/25/2021
Sample typeAcceptance A brief description of the sampleRubberized PG64-16
The quantity of what the sample constitutes1 of 1 can From where was the sample collectedManufacturer
First name of sampler or witnessed byJose Last name of sampler or witnessed byGranite Tech
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite - Coalinga Transportation Laboratory (TL) Numberc040386
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplierSan Joaquin Refining Co Inc
Performance GradePG 64-16 Lot number2
Sublot number Asphalt Rubber Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-21-14
DIME Test ID: 2021-06-21-14-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2021-07-01

Test Results


Determination: Unworked Penetration
Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 07/01/2021
Unworked Penetration, Test 1: 49 0.1 mm
Unworked Penetration, Test 2: 51 0.1 mm
Unworked Penetration, Test 3: 49 0.1 mm
Unworked Penetration: 50 0.1 mm
General comments (publicly viewable) (Max 1000 characters): Per 2018 standard specifications

Test was verified on 7/1/2021