Test 2021-05-12-62-6 (AASHTO T304-11) Summary

Project Information
Project IdentifiersProject ID: 214300
DEA: 07343404
EFIS: 0718000018
DIST-CO-RTE-PM07-LA-39-31.2
Work DescriptionIN LOS ANGELES COUNTY, ON ROUTE 39 AT NORTH FORK SAN GABRIEL RIVER BRIDGE (BR. NO. 53-3069) REPLACE BRIDGE
Location DescriptionIN LOS ANGELES COUNTY ABOUT 19 MILES NORTH OF AZUSA AT NORTH FORK SAN GABRIEL RIVER BRIDGE
Sample Information
Sample Taken Date5/12/2021 Sample Unique Key62
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/21/2021
Sample typeVerification A brief description of the sampleJMF 3/4" WMA-A-SP R15 0.25% EVO
The quantity of what the sample constitutes3 Bags Coldfeed Agg., 2 Bags Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Irwindale Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0377A-21
The fabricator/manufacturer/facility nameVulcan Materials Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035
The fabricator's/manufacturer's product name for the sample3/4 WMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number220830 IRW LTR A detailed description of where the material sample was collectedBelt Cut at Vulcan Materials-Irwindale
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-05-12-62
DIME Test ID: 2021-05-12-62-6
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-07-06
Test Results

What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 06/25/2021
Bulk dry specific gravity: 2.634
Average uncompacted voids:46.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/06/2021