Summary for Test 2015-07-07-4-2
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 209356 DEA: 07278204 EFIS: 0700000538 |
---|---|
DIST-CO-RTE-PM | 07-LA-10,110,118,134,210,710-Var |
Award Date | 04/18/2014 |
Closeout Date | 07/13/2016 |
Work Description | UPGRADE CURB RAMPS. |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 10/31/2014) |
Sample Information
Sample Taken Date | 07/07/2015 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/10/2015 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Cardiel | Last name of sampler or witnessed by | Bugarin |
Title of sampler | Structure Representative | Telephone number of sampler | Unknown |
Laboratory sample identification | 912-01F | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Robertsons | Transportation Laboratory (TL) Number | 10001F |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | 53 1748 |
Structure name | Central Ave OC Curb Ramp on Bridge |
Material Information
Material Type | Concrete | The concrete mix design number | SC590B38 |
---|---|---|---|
The truck number from where the sample was collected | 4813181 | The batch plant ticket number from where the sample was collected | 9700275 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Plant |
A detailed description of where the material sample was collected | Truck | Where the material sample would have been placed if not sampled | South East corner Curb Ramp |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-07-07-4
DIME Test ID: 2015-07-07-4-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-08-12
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 08/04/2015
Average diameter of cylinder 1: 6 in
Average diameter of cylinder 2: 6 in
Maximum load on cylinder 1: 106090 lb
Maximum load on cylinder 2: 108350 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3752.7 psi
Compressive strength of cylinder 2: 3832.7 psi
Compressive strength (to nearest 10 psi): 3790 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/12/2015 ✔