Test 2021-03-19-24-7 (AASHTO T324-14) Summary

Project Information
Project IdentifiersProject ID: 215405
DEA: 032G1604
EFIS: 0320000235
DIST-CO-RTE-PM03-YOL-45-0.6/12.9
Work DescriptionCOLD PLANE AC PAVEMENT AND REPLACE WITH HOT MIX ASPHALT.
Location DescriptionYOLO COUNTY NEAR KNIGHTS LANDING FROM SYCAMORE SLOUGH BRIDGE TO YOLO COUNTY LINE ROAD
Sample Information
Sample Taken Date3/19/2021 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/19/2021
Sample typeVerification A brief description of the sample3/4" HMA - A w/RAP
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byTeichert Personnel (SAMPLER) Last name of sampler or witnessed bySam Mosallem (WITNESS)
Title of samplerUnknown Laboratory sample identificationJMF21-015
The fabricator/manufacturer/facility nameTeichert - Woodland Plant Transportation Laboratory (TL) NumberC849138
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown JMF Verification ID JMF3513-2021-51
Test Details
DIME Sample ID: 2021-03-19-24
DIME Test ID: 2021-03-19-24-7
Testing Lab: CT D03 - North Region Materials Lab
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-06-30
Test Results

Input Type: Measured
Tester's full name: Jeff Herbert
Date of test: 05/06/2021
HMA Production: Field Plant Produced
Specified number of passes at 12.7 mm: 15000
Specified number of passes at inflection point: 10000
Type and Amount of Anti-Stripping Additive: N/A
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 122 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 5.88 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 5.01 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average:25000
Impression at specified number of passes average:5 mm
General comments (publicly viewable) (Max 1000 characters): JMF21-015.

Test was verified on 06/30/2021