Summary for Test 2021-04-12-66-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215033
DEA: 033H6504
EFIS: 0318000027
DIST-CO-RTE-PM03-NEV-49-8.3/8.7
Award Date08/07/2020
Closeout Date09/23/2021
Work DescriptionCONSTRUCT A TWO-WAY LEFT-TURN LANE AND 8' SHOULDERS.
Location DescriptionNEVADA COUNTY ON ROUTE 49 FROM 0.1 MILE SOUTH OF ROUND VALLEY ROAD TO 0.1 MILE NORTH OF QUAIL CREEK DRIVE
QA Service Level1 (Verified on 06/22/2020)

Sample Information

Sample Taken Date04/12/2021 Sample Unique Key66
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/13/2021
Sample typeVerification A brief description of the sample3/4" HMA - A
The quantity of what the sample constitutes32 boxes of mix From where was the sample collectedManufacturer
First name of sampler or witnessed byKRC Personnel (SAMPLER) Last name of sampler or witnessed byThao Xiong (WITNESS)
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationJMF21-022 Linked DIME Sample ID
The fabricator/manufacturer/facility nameKnife River Construction - Hallwood Transportation Laboratory (TL) NumberC779131
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-12-66
DIME Test ID: 2021-04-12-66-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-06-23

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Benjamin Dreher
Date of test: 05/26/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2238.8 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 2124.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.32 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 4.79 %
General comments (publicly viewable) (Max 1000 characters): JMF21-022.

Test was verified on 6/23/2021