Summary for Test 2021-06-18-4-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 215424
DEA: 024G4404
EFIS: 0214000013
DIST-CO-RTE-PM02-SIS-3-38.0/38.6
Award Date04/05/2021
Closeout Date08/14/2023
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD
QA Service Level1 (Verified on 01/19/2021)

Sample Information

Sample Taken Date06/18/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/19/2021
Sample typeQuality Control A brief description of the sampleConcrete 6 x 12 Cylinders
The quantity of what the sample constitutes2 6x12 concrete cylinders From where was the sample collectedManufacturer
First name of sampler or witnessed byMark Patrick Last name of sampler or witnessed byBaddu
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameConFab California, LLC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number98LV25AF
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected3398
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBed 1B, 3rd Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-06-18-4
DIME Test ID: 2021-06-18-4-1
Testing Lab: Con-Fab California Corporation - Lathrop
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-06-21

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Ferdinand Rosal
Date of test: 06/19/2021
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 208700 lb
Maximum load on cylinder 2: 214500 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 3 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 7485 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/21/2021