Test 2021-06-02-14-4 (AASHTO T315-16) Summary

Project Information
Project IdentifiersProject ID: 215424
DEA: 024G4404
EFIS: 0214000013
DIST-CO-RTE-PM02-SIS-3-38.0/38.6
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionSISKIYOU COUNTY ABOUT 6 MILES NORTH OF FORT JONES FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF LOWER MOFFETT CREEK ROAD
Sample Information
Sample Taken Date6/2/2021 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/14/2021
Sample typeAcceptance A brief description of the sampleTest binder #2
The quantity of what the sample constitutes2 cans From where was the sample collectedSource
First name of sampler or witnessed byD Last name of sampler or witnessed byOwens
Title of samplerPEI Tech Laboratory sample identification
The fabricator/manufacturer/facility nameValero Benicia Transportation Laboratory (TL) Number779364
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Asphalt Binder SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade TypeNot set HMA Design ID
Test Details
DIME Sample ID: 2021-06-02-14
DIME Test ID: 2021-06-02-14-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-06-17
Test Results

Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 06/16/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 22.242 kPa
Phase Angle (δ) (for the 10 cycles): 44.7 degree
Complex Modulus (G*) (for the 10 measurements): 2223.855 kPa
Test Temperature: 22.0 C
(G*) x sin(δ)=: 1564 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications PAV

Test was verified on 06/17/2021