Test 2021-06-07-17-5 (AASHTO T313-19) Summary

Project Information
Project IdentifiersProject ID: 215251
DEA: 021J4604
EFIS: 0220000081
DIST-CO-RTE-PM02-SIS-96-34.5/38.8,88.0/92.0
Work DescriptionHMA OVERLAY, REPLACE AC SURFACING, SHOULDER BACKING & TRAFFIC STRIPE.
Location DescriptionSISKIYOU COUNTY NEAR HAPPY CAMP FROM 0.1 MILE EAST OF OAK FLAT CREEK BRIDGE TO 0.1 MILE EAST OF BENJAMIN CREEK ROAD AND FROM 0.3 MILE WEST OF BEAVER CREEK BRIDGE TO 1.0 MILE WEST OF LUMGREY CREEK BRIDGE
Sample Information
Sample Taken Date6/7/2021 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/14/2021
Sample typeAcceptance A brief description of the samplePG58-22
The quantity of what the sample constitutes2 of 2 cans From where was the sample collectedSource
First name of sampler or witnessed byD Last name of sampler or witnessed byOwnes
Title of samplerPEI Laboratory sample identification
The fabricator/manufacturer/facility nameValero - Benicia, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form779372 Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number1
Sublot number1 Tank number
Time of sample HMA Supplier
Asphalt Binder SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade TypeNot set HMA Design ID
Test Details
DIME Sample ID: 2021-06-07-17
DIME Test ID: 2021-06-07-17-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2021-06-17
Test Results

Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 06/16/2021
Minimum test bath temperature at 240 s: -12.0 C
Maximum test bath temperature at 240 s: -12.0 C
Time of test load application: no data
File name of test data: no data
Time beam in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficient (R²): 0
Regression coefficient a: no data
Regression coefficient b: no data
Regression coefficient c: no data
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Load at 60.0 s: 977.0 mN
Beam deflection 60.0 s: 0.798 µm
Measured Stiffness Modulus 60.0 s: 98.700 mPa
Estimated Stiffness Modulus 60.0 s: 98.700 mPa
Difference between stiffness moduli 60.0 s: no data
Estimated m-value 60.0 s: 0.383
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 06/17/2021