Test 2021-06-05-4-2 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 214586
DEA: 081H7704
EFIS: 0817000132
DIST-CO-RTE-PM08-SBD-215-4.5/5.8
Work DescriptionINSTALL SIGN STRUCTURE, HMA, MODIFY RAMP METERING AND RETAINING WALL.
Location DescriptionSAN BENARDINO COUNTY IN SAN BERNARDINO FROM 0.5 MILE SOUTH OR ORANGE SHOW ROAD/AUTO PLAZA DRIVE OVERCROSSING TO 0.2 MILE NORTH OF INLAND CENTER DRIVE OVERCROSSING
Sample Information
Sample Taken Date6/5/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/7/2021
Sample typeQuality Assurance A brief description of the sample8 30 at 20cy out
The quantity of what the sample constitutes1 bag From where was the sample collectedManufacturer
First name of sampler or witnessed byMark Last name of sampler or witnessed byAlbert
Title of samplerqc Laboratory sample identification1419984
The fabricator/manufacturer/facility namebeador construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-36-0068
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2021-06-05-4
DIME Test ID: 2021-06-05-4-2
Testing Lab: CT D08 - Barstow Field Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-06-11
Test Results

What type of gradation is being tested?: Combined Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Calculated
Tester's full name: Julius
Date of test: 06/07/2021
Cumulative percent passing the 2 in. sieve:0 %
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:97 %
Cumulative percent passing the 3/4 in. sieve:72 %
Cumulative percent passing the 1/2 in. sieve:0 %
Cumulative percent passing the 3/8 in. sieve:46 %
Cumulative percent passing the #4 sieve:45 %
Cumulative percent passing the #8 sieve:38 %
Cumulative percent passing the #16 sieve:28 %
Cumulative percent passing the #30 sieve:18 %
Cumulative percent passing the #50 sieve:9 %
Cumulative percent passing the #100 sieve:4 %
Cumulative percent passing the #200 sieve:1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 06/11/2021