Test 2021-04-27-28-5 (AASHTO T304-11) Summary

Project Information
Project IdentifiersProject ID: 214511
DEA: 010E0004
EFIS: 0113000091
DIST-CO-RTE-PM01-HUM-101-84.4/84.8
Work DescriptionBRIDGE RAIL REPLACEMENT.
Location DescriptionHUMBOLDT COUNTY NEAR ARCATA FROM JACOBY CREEK BRIDGE TO GANNON SLOUGH BRIDGE
Sample Information
Sample Taken Date4/27/2021 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/25/2021
Sample typeDispute Resolution A brief description of the sample1/2" HMA NO RAP
The quantity of what the sample constitutes_ From where was the sample collectedManufacturer
First name of sampler or witnessed by_ Last name of sampler or witnessed by_
Title of sampler Laboratory sample identification21-JMF-0102
The fabricator/manufacturer/facility nameMercer Fraser - Fortuna Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-12-0002
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2021-04-27-28
DIME Test ID: 2021-04-27-28-5
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-06-07
Test Results

What test method is performed?: Method A
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 06/04/2021
Mass of measure: 187.8 grams
Bulk dry specific gravity: 2.568
Mass of sample and measure #1: 330.9 grams
Mass of sample and measure #2: 331.1 grams
Volume of cylinder: 100 mL
Mass of sample #1: 143.1 grams
Mass of sample #2: 143.3 grams
Uncompacted voids #1: 44.3 %
Uncompacted voids #2: 44.2 %
Average uncompacted voids:44.3 %
General comments (publicly viewable) (Max 1000 characters): Method A

Test was verified on 06/07/2021