Test 2021-04-27-28-3 (AASHTO T96-02r10) Summary

Project Information
Project IdentifiersProject ID: 214511
DEA: 010E0004
EFIS: 0113000091
DIST-CO-RTE-PM01-HUM-101-84.4/84.8
Work DescriptionBRIDGE RAIL REPLACEMENT.
Location DescriptionHUMBOLDT COUNTY NEAR ARCATA FROM JACOBY CREEK BRIDGE TO GANNON SLOUGH BRIDGE
Sample Information
Sample Taken Date4/27/2021 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/25/2021
Sample typeDispute Resolution A brief description of the sample1/2" HMA NO RAP
The quantity of what the sample constitutes_ From where was the sample collectedManufacturer
First name of sampler or witnessed by_ Last name of sampler or witnessed by_
Title of sampler Laboratory sample identification21-JMF-0102
The fabricator/manufacturer/facility nameMercer Fraser - Fortuna Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-12-0002
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2021-04-27-28
DIME Test ID: 2021-04-27-28-3
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2021-06-07
Test Results

Input Type: Measured
Tester's full name: Jay Horton
Date of test: 06/02/2021
Grading designation: C
Mass of sample (before test): 5002 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4724 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3777 grams
Percent loss after 100 revolutions:6 %
Percent loss after 500 revolutions:24 %
General comments (publicly viewable) (Max 1000 characters): At 100 rev and 500 rev

Test was verified on 06/07/2021