Test 2015-06-05-4-1 (CTM 521-November 2014) Summary

Project Information
Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
Sample Information
Sample Taken Date6/5/2015 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/10/2015
Sample typeQuality Control A brief description of the sample6X12
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byROMAN Last name of sampler or witnessed byGRANADOS
Title of samplerASR Laboratory sample identification866-1A
The fabricator/manufacturer/facility nameJOB Transportation Laboratory (TL) Number06051501A
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierOCEAN BLVD TO SR 47 IN LB
Structure nameBENT A8S FOOTING PILE CAP
Material Information
Material TypeConcrete The concrete mix design numberSFI-PCV2F
The truck number from where the sample was collected0171 The batch plant ticket number from where the sample was collected5144662
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedCHUTE Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set
Test Details
DIME Sample ID: 2015-06-05-4
DIME Test ID: 2015-06-05-4-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-07-31
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 07/31/2015
Average diameter of cylinder 1: 6 in
Average diameter of cylinder 2: 6 in
Maximum load on cylinder 1: 204460 lb
Maximum load on cylinder 2: 202760 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 56 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 7232.4 psi
Compressive strength of cylinder 2: 7172.3 psi
Compressive strength (to nearest 10 psi):7200 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/31/2015