Summary for Test 2021-06-03-4-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212252 DEA: 033F5604 EFIS: 0313000033 |
---|---|
DIST-CO-RTE-PM | 03-SUT,YUB-20-17.0/17.1,0.0/0.4 |
Award Date | 02/11/2021 |
Closeout Date | 01/25/2023 |
Work Description | INSTALL CAST-IN-STEEL SHELL CONCRETE PILE. |
Location Description | SUTTER AND YUBA COUNTIES IN YUBA CITY AND MARYSVILLE AT THE FEATHER RIVER BRIDGE AND OVERHEAD |
QA Service Level | 1 (Verified on 04/27/2018) |
Sample Information
Sample Taken Date | 06/03/2021 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/03/2021 |
Sample type | Per Request | A brief description of the sample | Sq Rebar |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Adams |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Service | Rebar Heat Number(s) | unknown |
Hoop Manufacturer Lot Number(s) | NA | Material Standard Code | ASTM A706 |
Material Grade | 40 | Rebar Size | #9 |
Diameter of Hoop | 2'-0" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Unknown |
Welding Company | unknown | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2021-06-03-4
DIME Test ID: 2021-06-03-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-06-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 06/03/2021
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | 9/29mm | 1 | 85947.37 | 85947 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 6/3/2021 ✔