Test 2021-05-24-20-1 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 22222
DEA: MAINTENANCE
EFIS: MAINTENANCE
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for materials used in maintenance projects.
Location DescriptionNot set
Sample Information
Sample Taken Date5/24/2021 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/25/2021
Sample typeAcceptance A brief description of the sampletop sand
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byzao Last name of sampler or witnessed byReid
Title of samplerCHMW Laboratory sample identification21-0101
The fabricator/manufacturer/facility nameEcho Summit Yard South Lake Tahoe Transportation Laboratory (TL) Numberc
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)not provided
The fabricator's/manufacturer's product name for the sampleTop Sand The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCinderlite top sand
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2021-05-24-20
DIME Test ID: 2021-05-24-20-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2021-06-02
Test Results

What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 05/28/2021
Individual mass retained on the 3/8 in. sieve: 0 grams
Individual mass retained on the #4 sieve: 37.4 grams
Individual mass retained on the #8 sieve: 203.4 grams
Individual mass retained on the #16 sieve: 157.9 grams
Individual mass retained on the #30 sieve: 65.7 grams
Individual mass retained on the #50 sieve: 28.3 grams
Individual mass retained on the #100 sieve: 11 grams
Individual mass retained on the #200 sieve: 4 grams
Individual mass retained on the pan: 0.2 grams
Total mass of sample tested: 508 grams
Cumulative percent passing the 3/8 in. sieve:100 %
Cumulative percent passing the #4 sieve:93 %
Cumulative percent passing the #8 sieve:53 %
Cumulative percent passing the #16 sieve:21 %
Cumulative percent passing the #30 sieve:9 %
Cumulative percent passing the #50 sieve:3 %
Cumulative percent passing the #100 sieve:1 %
Cumulative percent passing the #200 sieve:0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 06/02/2021